Peugeot 405
1987-1997 of release
Repair and operation of the car
Peugeot 405
+
1. Maintenance instruction
+
2. Maintenance
-
3. Engines
+
3.1. Petrol engines
-
3.2. Diesel engines
3.2.1. Technical characteristic
+
3.2.2. Adjustments of the engine
3.2.3. Removal and installation of the fuel pump of high pressure
3.2.4. Installation of the fuel pump of high pressure BOSCH
3.2.5. Installation of the fuel pump of high pressure Roto Diesel
3.2.6. Removal of water from the fuel filter
3.2.7. Removal of air from fuel system
3.2.8. Removal and installation of a nozzle
3.2.9. Check electrically the operated engine stop valve
3.2.10. Adjustment of the pump Bosch
3.2.11. Adjustment of the pump Roto Diesel
3.2.12. Removal and installation of a turbocompressor
+
3.2.13. The repair which is not demanding removal of the engine
3.2.14. Removal of the engine
3.2.15. Installation of the engine
3.2.16. Dismantling of the engine
3.2.17. Assembly of the engine
3.2.18. Oil pump
+
3.2.19. Cooling system
3.2.20. System of production of exhaust gases
+
3.3. Petrol engine 1,4 of dm3
+
3.4. System of ignition
+
4. Fuel system
+
5. Lubrication systems, coolings
+
6. System of release
+
7. Coupling
+
8. Transmissions
+
9. Power shafts
+
10. Steering
+
11. Suspension brackets
+
12. Brake system
+
13. Body
+
14. Electric equipment
3.2.6. Removal of water from the fuel filter
GENERAL INFORMATION
SYSTEM OF INJECTION BOSCH, PURFLUX FILTER
System of injection Bosch with the filter and a heater of Purflux
1 – injection pipelines,
2 – return pipelines,
3 – water discharge bolt,
4 – case,
5 – the filtering element,
6 – thermostatic element,
7 – filter head,
8 – manual fuel pump
Fuel Purflux filter
1 – deaerator,
2 – water discharge bolt,
3 – manual pump
PERFORMANCE ORDER
1.
Open the deaerator (1).
2.
Unscrew a bolt of discharge of water (2).
3.
Merge water and pollution.
4.
Screw up a bolt of discharge of water (2) and the deaerator (1).
SYSTEM OF INJECTION ROTO DIESEL
Fuel Roto Diesel filter
1 – deaerator,
2 – water discharge bolt,
3 – manual pump
PERFORMANCE ORDER
1.
Release a bolt of discharge of water (1).
2.
Press the button (2) of the manual pump for removal of water and pollution.
3.
Screw up a water discharge bolt.
On the homepage